1.INTRODUCTION :
YE-9280 is an exterior saturated carboxylic polyester resin curing with Primid XL-552 at
95/5 for thermosetting powder coating, Applied to exterior decorative and functional powder
coating with good durability, flow and high gloss etc.
2.CHARACTERISTICS OF THE RESIN
Appearance………………….… …pale granules
Acid value (mg KOH/g)…………… …..…28-36 (1)
Color……………………………...…… …max.2 (2)
Viscosity at 165°C (mPa...S)………18000--31000 (3)
Glass transition temperature (Tg) . approx.63°C (4)
Softening point(°C)……………… 100-106
(1)ISO-3682 (2)ASTM-D-2849
(3)ICI CONE & PLATE (4)DSC(METTLER)
3.APPLICATION:
TYPICAL POWDER FORMULA:
Barium sulfate…………………...…… …100 (1)
Titanium dioxide…………………...…… 300 (2)
Polyester YE-9280……………………….570
Primid XL-552 .……………………….. 30 (3)
Flow control agent……………………….. 10 (4)
Benzoin ………………………………..… 5
(1) Shaanxi Fuhua Chemical Co., Ltd
(2) DuPont R-902 or R706
(3) EMS YE-9280/ XL-552 =95/5
(4) YL-1080 (Silica Adsorption 65% Supplied by Yin Yang Resin Co., Ltd)
4.MANUFACTURING PROCEDURE AND TESTING
MANUFACTURING
a. Pre-mixing ( dry blend of the above components)
b. Homogeneous extrude at temperature of 115°C-125°C
c. Cool down and early pieces
d. Abrading powder to obtain a free -flowing powder maximum particle size of 80micron
COATING CONDITION:
Voltage…………………………………. 60-80kv
Air pressure………………………….. 1-2kg/cm2
Test panel……………………….0.35 mm steel panels
CURING CONDITION:
10 minutes at 200°C (object temperature)
TEST RESULT:
Film thickness………………………… 60-80µm
Gloss…………………………………… >90% (1)
Erichsen slow penetration………...…… >7mm (2)
Direct/reverse impact……………… >50kg-cm (3)
Conical mandrel………………. pass (4)
Crosshatch adhesion…………...…… Gt=0 (5)
(1)ASTM D-523(60°) (2) DIN 53165
(3)ASTMD-2194 (4) ASTM D-522
(5)DIN53151
5. PACKING AND STORAGE
25 kilogram paper bag or PE bag; Stored in a cool dry indoor place at temperature of
-20°C-35°C, Avoid long-term exposure to direct sunlight. In the above-mentioned storage
conditions the shelf life of resins for 1 year. Experience has shown that the storage life of the
resin up to 3 years, it is proposed that the testing products beyond the shelf-life products can still
be used for qualified.
The above-mentioned indications are based on carefully made tests. No liability can be assumed
in the event of any inaccuracy or incompleteness being found in the value listed above and
consequently we recommend evaluation in your own laboratories prior to use.